Commercial facility

Northgate Quantum Characterisation Laboratory

Northgate Instruments LtdOxford, Oxfordshire

Access: Open to external usersProfile: Provider verified profile

Commercial characterisation service for quantum sensors, combining climatic test chambers with a magnetically shielded measurement room for sensitivity and noise-floor characterisation across temperature.

Provider organisation
Northgate Instruments Ltd
Location
Oxford, Oxfordshire
Lead time
14–28 days (Provider stated)

Capabilities

What the facility can do, with operating ranges and the evidence behind each claim.

  • Quantum sensor characterisation

    Characterisation

    Sensitivity, noise floor and heading-error characterisation of optically pumped and NV-diamond magnetometers.

    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027
  • Environmental testing

    Qualification

    Temperature-controlled characterisation in climatic chambers.

    Operating range

    • Temperature: −40 °C to +85 °C
    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027
  • Magnetically shielded measurement

    Characterisation

    Operating range

    • Residual magnetic field: Residual field below 1 nT
    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027

Equipment

  • Climatic test chamber

    Environmental

    Manufacturer / model: Generic CT-850

    Configuration: Optical feedthroughs; non-magnetic sample stage

    Operating range

    • Temperature: −40 °C to +85 °C
    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027
  • Magnetically shielded room

    Magnetics

    Configuration: Four-layer mu-metal, active compensation

    Operating range

    • Residual magnetic field: Residual field below 1 nT
    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027

Processes / services

Test methods / standards

Materials / device compatibility

Shown where the provider or a source supplies it.

  • Diamond (including NV-diamond)

    MaterialSupported

    NV-diamond sensor heads accepted in standard mounts.

    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027
  • Magnetic mounting materials

    MaterialNot supported

    Ferromagnetic parts are not permitted inside the shielded room.

    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027

Expertise

Specialist technical capabilities available alongside the equipment.

External access

Access state:Access: Open to external users

The provider retains control of site safety, equipment operation, training, sample acceptance and experimental procedure. Submitting an access request does not authorise any physical work.

Lead time & commercial model

Lead time
14–28 days (Provider stated)
Lead times change. Confirm dates for your specific request with the provider.
Commercial model
DailyProject quote
Where public. Prices and terms are agreed with the provider.

Restrictions

Known restrictions on safety, materials, security, export control, IP, training and eligibility.

  • Safety

    Provider restrictions apply

    Class 3B/4 lasers require a completed laser safety declaration before arrival.

    Provider verifiedSource type: Provider verified
    Source
    Capability statement submitted by Northgate Instruments
    Last reviewed
    15 Jul 2026
    Last verified
    12 Aug 2026
    Review due
    12 Feb 2027

Prerequisites

What the provider may need before work can start.

  • Sample declaration form

    Safety

    Materials, laser classes and power requirements.

  • Mutual NDA

    Nda confidentiality

Sources

Where the information on this profile came from.

  1. Capability statement submitted by Northgate Instruments

    Provider verified
    Reference
    Provider submission, July 2026
    Accessed
    15 Jul 2026
    Permitted-use basis
    Not recorded

Verification history

Changes to verification state are recorded, not overwritten.

  1. 12 Aug 2026

    Capability: Quantum sensor characterisation

    Unverifiedchanged toProvider verified

    Method: Provider confirmation of capability statement · Verified by Northgate Instruments Ltd

  2. 12 Aug 2026

    Capability: Environmental testing

    Unverifiedchanged toProvider verified

    Method: Provider confirmation of capability statement · Verified by Northgate Instruments Ltd

  3. 12 Aug 2026

    Capability: Magnetically shielded measurement

    Unverifiedchanged toProvider verified

    Method: Provider confirmation of capability statement · Verified by Northgate Instruments Ltd

Facility profiles may contain information supplied directly by providers as well as information obtained from identified public sources. Providers are responsible for information they submit or verify. Qapacity may identify inconsistencies or stale information but does not independently certify a provider's technical capability unless expressly stated under a separate service.

Information provided through Qapacity is intended to support infrastructure discovery and access planning. Facility capabilities, availability and suitability can change and may depend on details not represented on the platform. Users should obtain appropriate confirmation from the relevant provider before relying on a facility for a specific technical requirement.

A facility appearing on Qapacity does not mean that Qapacity has certified, accredited or approved that facility. Access state shown: Open to external users.

Suggest a correction

Seen something incorrect, missing or out of date? A reviewer will assess it against your evidence.

Describe what is incorrect, missing or out of date, and what it should say.

Optional. Explain how you know — for example a published specification or your direct experience.

Optional. A public page supporting the correction.

Used only if a reviewer needs to ask about your evidence. It is not shown on the profile.

Suggestions are reviewed before any change is made, and the evidence and reason are kept with the record. See the privacy notice.